Check your equipment:
-
Inspect the vibrator system for damage. Never use a
damaged vibrator.
-
Have all components of the vibrator system received
proper maintenance?
VME Electric Motors: Monitor brushes & bearings. No lubrication
required.
Flexible Shafts: Re-grease core after every 50 hours of use or if core
rattles excessively.
Vibrator Head: Monitor bearings. ViberŽ heads are permanently lubricated
at the factory. No further lubrication required.
-
Are all vibrator system connections tight? Apply TeflonŽ
tape to the casing threads, before attaching the head, to give a
watertight connection.
-
Do you have the proper power source?
VME 1500, 1500L, 2500, 2500L / 115V models = 115 volt, 15 amp service
VME 3000 / 115V model = 115 volt, 20-amp service VME 1500, 2500, 3000 /
230 volt models = 230 volt, 15 amp service
-
If using an electric motor, is it properly grounded?
-
If an extension cord is used, is it the proper size?